Specifications |
LAB5020 |
|
|
Description |
Glass to glass |
|
|
Dimensions. mm |
Ø 43-0.25 × 22-0.52 |
|
|
Contacts type |
Flying leads |
|
|
Photocathode useful diameter. mm |
17.5 |
|
|
Photocathode type |
Multialkali |
|
|
Phosphor |
P43 |
|
|
Material of input/output window |
Glass thickness 1.2 mm / Glass thickness 1.2 mm |
|
|
Parameters |
Minimum |
Typical |
|
Luminous photocathode sensitivity. µA/lm. min |
500 |
600 |
|
Radiant (850 nm). mA/W |
35 |
50 |
|
Limiting resolution. lp/mm |
50 |
51 |
|
Signal-to-noise ratio |
20 |
22 |
|
Gain |
20 000-30 000 *on Buyer’s request |
|
|
FOM |
1000 |
1122 |
|
Max. output brightness. cd/m2 |
2-8 |
|
|
E.B.I.. μlx. max |
0.25 |
|
|
Input voltage. V |
2-3.6 |
|
|
Input current. mA. max |
25 |
|
|
Weight. max |
55 |
|
|
MTTF. h |
10 000 |
|
|
|
||
Purity of visual area
|
Number of zone |
Zone size. mm |
Dark spots diameter |
Permissible total defect area. mm2 |
||
|
Not considerable |
Allowable |
||||
|
by size. mm |
by quantity |
||||
|
1 |
9.0 |
0.06 |
0.1 |
1 |
0.1 |
|
2 |
9-14.4 |
0.06 |
0.15 |
1 |
0.15 |
|
3 |
14.4-17.5 |
0.06 |
0.2 |
2 |
0.15 |